You are here: Home > Catalogue > AC->DC Switching Power Supplies > Redundant + Hot Swap Series

pointAC->DC Switching Power Supplies
point1 Redundant + Hot Swap Series
  GP22601c
AC I/P VERSION
ISSUED : 9-26-2001
DWG NO: 0001
REV : C



1. INPUT:
1.1 AC INPUT VOLTAGE :
Active Power factor corrected with 85 VAC to 264VAC
Continuous Rangeoperation, Internally Fused: 5A 250 VAC,
5mm x 20mm Axial Type.PFC: compliant to l at EN61000-3-2.
Power factor is 0.98 typica full load.
1.2 AC INPUT FEQUENCY :47-63 Hz.
1.3 AC INPUT CURRENT : 6A for 115VAC(MAX)
3A for 230VAC(MAX)
1.4 MAX. IN-RUSH CURRENT : 20A for 115VAC
40A for 230VAC
(AT COLD START)
2. OUTPUT :
(1) (2)
2.1 O/P VOLTAGE : (VDC) +3.3 +12
  Adjustment Range : Required is 3.0VDC - 3.6VDC using single
potentiometer at 3.3V Output And 12V Output does not require an
adjustment but should be guaranteed to be 12VDC @ 2.5Amps
2.2 MIN LOAD CURRENT : (A) 0 0.5
2.3 MAX LOAD CURRENT: (A) 70 2.5
(with air force 10CFM minimum)
2.4 LINE REGULATION : (%) +1 -1 +1 -1
2.5 LOAD REGULATION : (%) +1 -1 +5 -5
2.6 TOLERANCE : (%) +1 -1 +5 -5
2.7 RIPPLE (P-P) : (mv) 30 100
2.8 NOISE & RIPPLE : (mv) 50 120
(P-P)
3. OVERALL PERFORMANCE:
3.1 TOTAL OUTPUT POWER :260W (full load nominal input voltage)
The Power Supply's total output power will have to be larger if the
requirement for power dissipation at the output's Oring devices is taken
into account. 260W is the actual net power required by the load.
Both outputs should feature Oring elements.
3.2 EFFICIENCY :65 % typical at full load nominal input voltage
3.3 HOLD UP TIME : 16 msec at max load and nominal line voltage.
3.4 SWITCHING FREQUENCY : 85 kHz minimum.
3.5 TEMPERATURE COEFFICIENT : +-0.05% per.C
3.6 RISE TIME : 70ms/max (at nominal I/P Voltage and 80% Load)
4. FEATURES:
4.1 OVERVOLTAGE PROTECTION: When V1 or V2 outputs
exceeds overvoltage set/trip point (120% to 130% of nominal voltage),
the entire power supply shuts down. To reset, cycle input power.
4.2 SHORT CIRCUIT PROTECTION (Individual Outputs) : All
outputs are protected. Output recovers when short is removed.
4.3 CURRENT LIMITING (Individual Outputs):Limited to 110%-
135% maximum output current ratings. Output recovers when overload
is removing
4.4 OVER TEMPERATURE PROTECTION: Power supply protected
in the event of excessive operating ambient degree C, and should be
automatic recovery when the temperature was back to normal
temperature in specification.
4.5 REMOTE SENSE: Separate sense terminals V1 and V2 will
compensate for total line loss of 5%. Internal circuits assure that the
output voltage will only change slightly should the sense line open.
The compensate value are up to 0.165 VDC at 3.3v and 0.6v at 12v.
Both outputs will be Oring elements, and the 3.3V output should also
feature Load Current Sharing via single wire current sharing method.
Parallel connection capability with " Current Sharing" for up to 4 units
(total available power 1040W).
4.6 REMOTE ON/OFF - ENABLE/INHIBIT: On: Leave circuit open
or apply TTL "HI". Turn Off: Apply a "TTL" "LOW" or short pin
to return.
4.7 DC GOOD LED INDICATOR: Green LED On indicates ALL DC
outputs is Good at front panel and should be become dark when has any
abnormal voltages at both outputs.
5. ENVIRONMENTAL:
5.1 OPERATING TEMPERATURE & OUTPUT POWER: 100%
rated load at 0 to 65¢XC @ cooling of 10CFM environment; derating
.linearly to 50% at 70¢XC (2.5% / ¢XC).
5.2 HUMIDITY : 10% to 90% RH.
5.3 STORAGE TEMPERATURE : -20 .C TO 85 .C
5.4 STORAGE HUMIDITY : 20% to 85% RH.
5.5 BURN IN : 4 hours 100% load at 40 .C + - 5 .C
6. RELIABILITY
6.1 MEAN TIME BETWEEN FAILURE: 100K hrs. Minimum.
At full load for 25 .C Ambient temperature. And 50k hrs at full load for
40 degs.
7. CONNECTORS : CROWN EDGE P/N# 284-0022-01300.
8. MECHANICAL:
8.1 MOUNTING TYPE: PLUGIN (HOT SWAP).
8.2 DIMENSIONS: 250MM(L) X 130MM X 60MM(W).
9. Safety Approvals
DESIGNED TO MEET IEC950, EN60950 (TUV) , UL1950, cUL,
CE Mark for LVD
10. EMI/RFI Compliance
EMI Compliance: Conducted and Radiated Noise as per FCC- B,
  EN55022-B AND EN61000-3-2