| 1. |
INPUT:
|
| 1.1
|
AC
INPUT VOLTAGE : |
|
Active
Power factor corrected with 85 VAC to 264VAC |
|
Continuous
Rangeoperation, Internally Fused: 5A 250 VAC, |
|
5mm x
20mm Axial Type.PFC: compliant to l at EN61000-3-2. |
|
Power
factor is 0.98 typica full load. |
|
|
| 1.2 |
AC
INPUT FEQUENCY :47-63 Hz. |
|
|
| 1.3 |
AC
INPUT CURRENT : |
6A for
115VAC(MAX) |
|
|
3A for
230VAC(MAX) |
|
|
| 1.4 |
MAX.
IN-RUSH CURRENT : |
20A for
115VAC |
|
|
40A for
230VAC |
|
|
(AT COLD START) |
|
|
| 2. |
OUTPUT
: |
|
|
(1) |
(2) |
| 2.1 |
O/P
VOLTAGE : (VDC) |
+3.3 |
+12 |
| |
Adjustment
Range : Required is 3.0VDC - 3.6VDC using single |
|
potentiometer
at 3.3V Output And 12V Output does not require an |
|
adjustment
but should be guaranteed to be 12VDC @ 2.5Amps |
| 2.2
|
MIN
LOAD CURRENT : (A) |
0 |
0.5 |
| 2.3 |
MAX
LOAD CURRENT: (A) |
70 |
2.5 |
|
(with
air force 10CFM minimum) |
| 2.4
|
LINE
REGULATION : (%) |
+1 -1 |
+1 -1 |
| 2.5
|
LOAD
REGULATION : (%) |
+1 -1 |
+5 -5 |
| 2.6 |
TOLERANCE
: (%) |
+1 -1 |
+5 -5 |
| 2.7 |
RIPPLE
(P-P) : (mv) |
30 |
100 |
| 2.8 |
NOISE
& RIPPLE : (mv) |
50 |
120 |
|
(P-P) |
| 3.
|
OVERALL
PERFORMANCE: |
| 3.1 |
TOTAL
OUTPUT POWER :260W (full load nominal input voltage) |
|
The
Power Supply's total output power will have to be larger if the |
|
requirement
for power dissipation at the output's Oring devices is taken |
|
into account.
260W is the actual net power required by the load. |
|
Both outputs
should feature Oring elements. |
|
|
| 3.2 |
EFFICIENCY
:65 % typical at full load nominal input voltage |
|
|
| 3.3 |
HOLD
UP TIME : 16 msec at max load and nominal line voltage. |
|
|
| 3.4 |
SWITCHING
FREQUENCY : 85 kHz minimum. |
|
|
| 3.5
|
TEMPERATURE
COEFFICIENT : +-0.05% per.C |
|
|
| 3.6 |
RISE
TIME : 70ms/max (at nominal I/P Voltage and 80% Load) |
|
|
| 4. |
FEATURES: |
|
|
| 4.1 |
OVERVOLTAGE
PROTECTION: When V1 or V2 outputs |
|
exceeds
overvoltage set/trip point (120% to 130% of nominal voltage), |
|
the entire
power supply shuts down. To reset, cycle input power. |
|
|
| 4.2
|
SHORT
CIRCUIT PROTECTION (Individual Outputs) : All |
|
outputs
are protected. Output recovers when short is removed. |
|
|
| 4.3 |
CURRENT
LIMITING (Individual Outputs):Limited to 110%- |
|
135% maximum
output current ratings. Output recovers when overload |
|
is removing
|
|
|
| 4.4
|
OVER
TEMPERATURE PROTECTION: Power supply protected |
|
in the
event of excessive operating ambient degree C, and should be |
|
automatic
recovery when the temperature was back to normal |
|
temperature
in specification. |
|
|
| 4.5 |
REMOTE
SENSE: Separate sense terminals V1 and V2 will |
|
compensate
for total line loss of 5%. Internal circuits assure that the |
|
output
voltage will only change slightly should the sense line open.
|
|
The
compensate value are up to 0.165 VDC at 3.3v and 0.6v at 12v. |
|
Both outputs
will be Oring elements, and the 3.3V output should also |
|
feature
Load Current Sharing via single wire current sharing method. |
|
Parallel
connection capability with " Current Sharing" for up
to 4 units |
|
(total
available power 1040W). |
|
|
| 4.6 |
REMOTE
ON/OFF - ENABLE/INHIBIT: On: Leave circuit open |
|
or apply
TTL "HI". Turn Off: Apply a "TTL" "LOW"
or short pin |
|
to
return. |
|
|
| 4.7 |
DC
GOOD LED INDICATOR: Green LED On indicates ALL DC |
|
outputs
is Good at front panel and should be become dark when has any
|
|
abnormal
voltages at both outputs. |
|
|
| 5. |
ENVIRONMENTAL: |
| 5.1 |
OPERATING
TEMPERATURE & OUTPUT POWER: 100% |
|
rated
load at 0 to 65¢XC @ cooling of 10CFM environment; derating
|
|
.linearly
to 50% at 70¢XC (2.5% / ¢XC). |
| 5.2 |
HUMIDITY
: 10% to 90% RH. |
| 5.3 |
STORAGE
TEMPERATURE : -20 .C TO 85 .C |
| 5.4 |
STORAGE
HUMIDITY : 20% to 85% RH. |
| 5.5 |
BURN
IN : 4 hours 100% load at 40 .C + - 5 .C |
|
|
| 6. |
RELIABILITY |
| 6.1 |
MEAN
TIME BETWEEN FAILURE: 100K hrs. Minimum. |
|
At full
load for 25 .C Ambient temperature. And 50k hrs at full load for
|
|
40 degs. |
|
|
| 7. |
CONNECTORS
: CROWN EDGE P/N# 284-0022-01300. |
|
|
| 8. |
MECHANICAL:
|
| 8.1 |
MOUNTING
TYPE: PLUGIN (HOT SWAP). |
|
|
| 8.2 |
DIMENSIONS:
250MM(L) X 130MM X 60MM(W). |
|
|
| 9. |
Safety
Approvals |
|
DESIGNED
TO MEET IEC950, EN60950 (TUV) , UL1950, cUL, |
|
CE Mark
for LVD |
|
|
| 10. |
EMI/RFI
Compliance |
|
EMI
Compliance: Conducted and Radiated Noise as per FCC- B, |
| |
EN55022-B
AND EN61000-3-2 |
| |
|